ELECTRICALSHOCK,FIREOR EXPLOSION
HAZARD
Failureto follow this warning could result in personal
iniury, death or property damage.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position and
install a lockout tag. There may be more than one
disconnect switch. Lock out and tag switch with a suitable
warning label. Verify proper operation after servicing.
This instruction covers the installation of gas conversion kit Part
No. KGANP5201VSP to convert the following furnaces from
natural gas usage to propane gas usage. See appropriate section
for your furnace type.
Section 1--59MN7 & 987M 4-Way Multipoise, Hot Surface
Ignition, Modulating Condensing Furnaces. This kit is designed
for use in furnaces with 60,000 through 120,000 Btuh gas input
rates.
Section 2--59TN6, 986T, & PG96V_T 4-Way Multipoise, Hot
Surface Ignition, 2-Stage, Variable-Speed Condensing Furnaces.
59TN6A applies to 60,000 to 120,000 Btuh gas input rates.
986TA & PG96VAT applies to 40,000 to 120,000 Btuh gas input
rates.
Section 3--58CVA, 58CVX, 315AAV, 315JAV, PG8MVA, &
PG8JVA 33.3-In. (846 mm) High, Induced-Combustion, Hot-
Surface Ignition, 2-Stage, Variable-Speed, Non-Condensing
Furnaces. This kit is designed for use in furnaces with 42,000
through 154,000 Btuh gas input rates.
DESCRIPTION AND USAGE
This kit is designed for use in the furnaces listed below. See Table
1 for kit contents. To accommodate many different furnace
models, more parts are shipped in kit than will be needed to
complete conversion. When installation is complete, discard extra
parts.
Table 1 - KGANP5201VSP Contents
COMPONENT
QTY DESCRIPTION
NUMBER
616166-629 1 PCS CARTON
319965-445 1 PCS LABEL, SHIPPING
320069-602 2 PCS TAPE
326269-701 1 PCS PARTS ASSY
326269-703 1 PCS PARTS ASSY
326269-704 1 PCS PARTS ASSY
326272-702 1 PCS PARTS ASSY
326751-702 1 PCS PARTS ASSY
367704-701 1 PCS LABEL KIT
367704-702 1 PCS LABEL KIT
367704-703 1 PCS LABEL KIT
367932-701 1 PCS BAG ASSY
367932-702 1 PCS BAG ASSY
337932-703 1 PCS BAG ASSY
AG- KGANPVSP-XX 1 PCS INSTRUCTIONS
EF69ZWO02 1 PCS VALVE CVRSN KIT
EF39ZW026 2 PCS VALVE CVRSN KIT
HKO2LBO08 1 PCS SWITCH, PRESSURE
W182X06- -04- -012 1 PCS WIRE ASSY
W182X26- -04- -018 2 PCS WIRE ASSY
W182X66- -04- -012 1 PCS WIRE ASSY
W182X66- -04- -018 1 PCS WIRE ASSY
W182Y66- - 11 - -006 1 PCS WIRE ASSY
W182Y66-- 11--014 1 PCS WIRE ASSY
W182Y66- -26- -016 1 PCS WIRE ASSY
SECTION 1
Table 2 - Condensing Furnaces
MODELNUMBERS BEGINNINGWITH:
59MN7 987M
INSTALLATION
1. Set room thermostat to lowest setting or "OFF".
2. Remove outer doors.
3. Disconnect power at external disconnect, fuse or circuit
breaker.
4. Turn off gas at external shut-off or gas meter.
5. Remove outer doors and set aside.
6. Turn electric switch on gas valve to OFF.