REINSTALL BURNER ASSEMBLY
To reinstall burner assembly:
1. Attach flame sensor to burner assembly.
2. Insert one-piece burner in slot on sides of burner box and
slide burner back in place.
3. Reattach HSI wires to HSI.
4. Verify igniter to burner alignment. See Fig. 26 and 27.
II !
(64.4)
Fig. 26 - Igniter Position - Top View
Al1405
2-in.
(50 mm)
3/16-in.
(4.6 mm)
A12392
Fig. 27 - Igniter Position - Side View
CONVERT GAS VALVE
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow this warning could result in personal
iniury, death or property damage.
Before installing, modifying, or servicing system, main
electrical disconnect switch nmst be in the OFF position and
install a lockout tag. There may be more than one
disconnect switch. Lock out and tag switch with a suitable
warning label. Verify proper operation after servicing.
1. Refer to Fig. 28.
2. Be sure gas and electrical supplies to furnace are off.
3. Remove caps that conceal adjustment screws for high-heat
and low-heat stage gas valve regulators. (See Fig. 28.)
4. Remove the high-heat and low-heat regulator adjustment
screws.
5. Remove the high-heat and low-heat gas regulator springs
(silver).
6. Install the high-heat and low-heat propane gas regulator
springs (white).
7. Install the high-heat and low-heat regulator adjustment
screws.
8. Turn high-heat stage adjusting screw clockwise (in) 13.5
full turns. This will increase the manifold pressure closer
to the propane high-heat set point. (See Fig. 28.)
9. Turn low-heat stage adjusting screw clockwise (in) 9.5
full turns. This will increase the manifold pressure closer
to the propane low-heat set point. (See Fig. 28.)
10. Do not install regulator seal caps at this time.
'_ "_<"_ Regulator Seal Cap
TWO-STAGE _ %_@_-_9 *
_ _% Regulator Ad ustment
4: _ ..... Screw
ON/OFF Switch
1/2" NPT Inlet
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage
The G or J gas valve must be converted and pre-adjusted
before operating on propane gas. The E valves nmst be
pre-adjusted before operating on propane gas. If left this
way, sooting and corrosion will occur leading to early heat
exchanger failure.
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal
iniury, death or property damage.
Gas supply MUST be shut off before disconnecting
electrical power and proceeding with conversion.
1/8" NPT Inlet
Pressure Tap
1t8" NPT Manifold
Pressure Tap
Fig. 28 - Two-Stage Gas valve
A11472
INSTALL LOW GAS PRESSURE SWITCH
NOTE: Install the Low Gas Pressure Switch before installing the
manifold on the burner assembly.
There are 2 ways to mount the Low Gas Pressure Switch.
All 14 3/16-in. (36t) ram) Casings or Vent Passes Between
Inducer Assembly and Burner Assembly
14