Controls
Microprocessor controls
Microprocessor controls provide the safety, interlock, ca-
pacitycontrol, andindications necessaryto operatethechiller
in a safe and efficient manner.
Control system
The microprocessor control on each 16JB double-effect
chiller isfactory mounted, wired,and tested to ensurechiller
protection and efficient capacity control. In addition, the
program logic ensures proper starting, stopping, and recy-
cling of the chiller and provides a communication link to
the Carrier Comfort Network (CCN).
Features
Control system
• Component Test and Diagnostic Check
• Menu-Driven Keypad Interface for Status Display,
Set Point Control, and System Configuration
• CCN Compatible
• Primary and Secondary Status Messages
• Individual Start/Stop Schedules for Local and
CCN Operation Modes
• Recall of Up to 25 Alarm/Alert Messages with
Diagnostic Help
• Extensive Diagnostic and Service Capabilities
• Advanced Crystallization Protection
Safety cutouts
• Solution Pump Motor Overload/High Temperature
• Refrigerant Pump Motor Overload/High Temperature
• Low Chilled Water Temperature Cutout
• Generator Solution Temperature Cutout
• Generator Pressure Cutout
• Evaporator and Condenser Water Flow
• Intermittent Power Loss
• Generator High Level
Protective limits
• Low Chilled and Cooling Water Flow
• Solution Pump Overload/High Temperature
• Refrigerant Pump Overload/High Temperature
• Transducer Reference Voltage
• Generator High Temperature
• Solution Pump Pressure
• Entering and Leaving Chilled Water Temperature
• Cooling Water Temperature Entering and
Leaving Absorber
• Cooling Water Temperature Leaving Condenser
• Weak Solution Temperature Leaving Absorber
• Strong Solution Temperature Entering Heat Exchanger
• Strong Solution Temperature Leaving Generator
• Solution Temperature Entering Spray Header
• Low Refrigerant Temperature
• Condenser Vapor Condensate Temperature
Overrides
• Refrigerant Low Temperature
• Generator High Saturation Temperature
• Generator High Solution Temperature
• Generator High Solution Level
• Recycle Control
• Solution Concentration Control
• Desolidification Mode
Capacity control
• Leaving Chilled Water Control
• Entering Chilled Water Control
• Ramp Loading
• Steam Demand Limit
• Chilled Water Reset
Indications
• Chiller Operating Status Message
• Absorption Cycle State Points
• Dilution Cycle
• Power-On
• Pre-Alarm Alert
• Alarm
• Safety Shutdown Messages
• Elapsed Time (Hours of Operation)
• Control Valve Position
16JB MICROPROCESSOR CONTROL CENTER
(EXTERNAL VIEW)
LID
WINDOW
SOLUTION
PUMP
REFRIGERANT
PUMP
DILUTION
VALV E
EXHAUST
PURGE
LLC
VALV E
DILUTION CYCLE
MANUAL/AUTO
GG
W
R
W
19