Features/Benefits (cont)
Factory-trained service organiza-
tion Carrier’s extensive service
organization offers trained and experi-
enced service technicians in every
major city. In addition to routine main-
tenance and repair services,
Carrier also offers a wide array of pre-
ventative maintenance, full mainte-
nance, and/or extended service con-
tracts which can be custom-tailored to
fulfill any service requirements.
Leakproof hermetic pumps cut
maintenance costs Carrier’s
proven solution and refrigerant pump/
motors are leakproof, completely
self-contained, and hermetically sealed.
The hermetic design eliminates the
need for a separate, complicated, and
possibly leakprone seal water system
and auxiliary water piping, while
providing leak tightness and longer
machine life. There are no pack-
ing glands or seals to maintain air
cannot leak in, fluids cannot leak
out. Specially designed bearings ab-
sorb both radial and axial thrusts
to ensure correct fit at all times. There
is no possibility of external contami-
nation since the fluid being pumped
lubricates and cools the pump and
motor assemblies. In addition, both
the rotor and stator are separated by
a stainless steel liner that protects
the windings from the fluid being
pumped. As an additional safety fea-
ture, thermal overload switches are
embedded in the stator to protect
against high winding temperature. The
pumps are field serviceable and in-
spection is recommended after 6
years of operation. Pump isolation
valves are not included on 16JB ma-
chines to minimize potential leak
paths into the machine. The pump
isolation valves are not required
because of the exceptionally high
reliability of the pump/motor
assemblies.
Superior corrosion protection
Absorption chillers must be protected
from the internal corrosion that is
always present when lithium bromide
solution is in contact with internal
machine surfaces. The Carrier 16JB
absorption chiller incorporates a
highly effective corrosion inhibitor
to provide an extra margin of
protection against internal corrosion.
Other inhibitors may necessitate
the use of exotic tube materials in cer-
tain heat exchangers since they are
less effective and require frequent
maintenance and analysis. The supe-
rior corrosion protection of the inhibi-
tor allows for the use of standard
copper tubes throughout the machine
(except for the generator [90/10
cupro-nickel]). This results in long ma-
chine life and dependable operation.
Rugged machine construction
Every Carrier 16JB offers numer-
ous standard features designed to
provide reliable, trouble-free opera-
tion. The machine is fabricated to
meet stringent manufacturing and
design requirements. Non-clogging,
corrosion-proof spray nozzles ensure
against both corrosion and possible
blockage for continuous, reliable
operation. U-bend tubes of 90/10
cupro-nickel in the generator allow
the tube bundle to expand and adjust
freely when subjected to rapid tem-
perature changes. Allowing for this
thermal growth and expansion reduces
tube wear and helps prevent prema-
ture tube failure. The numerous stand-
ard features mean that every 16JB
single effect chiller is built to withstand
the most rigorous duty, whether it is
used for comfort cooling or light
process applications.
Automatic motorless purge ex-
tends machine life, ensures opti-
mum efficiency and performance
The purge system on an absorp-
tion chiller is critical to ensuring long
machine life and efficient opera-
tion. All absorption chillers operate in
a vacuum and generate hydrogen
(and other noncondensable gases) in
small quantities, whether they are
vacuum tight or properly inhibited.
These gases are present in sufficient
volume to interfere with proper
machine operation, making it impera-
tive that they be removed to protect
against internal corrosion, lithium bro-
mide solution crystallization, and/or
reduction of chiller capacity. The
Carrier motorless purge system pro-
tects against these potential hazards
by operating continuously during
machine operation.
How the motorless purge operates
The absorber eductor device dis-
charges the solution and noncondens-
ables into the overflow line where
noncondensables are separated from
the solution. Noncondensables flow up
the overflow line and into the con-
denser. The solution flows through the
secondary heat exchanger and into
the sump of the absorber.
The condenser eductor device draws
the noncondensables from the con-
denser and discharges the solution
and noncondensable mix into the stor-
age chamber. The mix separates, the
noncondensables remain and the solu-
tion returns through the solution
return line to the secondary heat ex-
changer and into the sump of the
absorber.
As noncondensables accumulate in
the external storage chamber, they are
isolated from the chiller and cannot
re-enter the chiller even during
shutdown. These gases must be peri-
odically exhausted (normally once a
day or as indicated by the purge indi-
cator) from the storage chamber by
a simple procedure which can be per-
formed while the chiller is running.
Evacuation is accomplished by manu-
ally positioning valves to pressurize
the storage chamber with lithium bro-
mide solution and then exhausting
the noncondensable gases into the
atmosphere.