APPENDIX A — 19XRV LIQUIFLO™ 2 ICVC PARAMETER INDEX (cont)
PARAMETER
MENU
SOFTKEY
TABLE SCREEN NAME CONFIGURABLE
Line Volt Imbalance Time SERVICE VFD CONFIG DATA VFD_CONF X
Line Voltage Imbalance SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Line Voltage Imbalance STATUS POWER
Line Voltage Imbalance STATUS VFD_STAT
Line Voltage % Imbalance SERVICE VFD CONFIG DATA VFD_CONF X
Line Voltage Ph1 (RS) SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Line Voltage Ph1 (RS) STATUS POWER
Line Voltage Ph2 (ST) SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Line Voltage Ph2 (ST) STATUS POWER
Line Voltage Ph3 (TR) SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Line Voltage Ph3 (TR) STATUS POWER
Load Balance Option SERVICE CONTROL ALGORITHM STATUS LL_MAINT
Load Balance Option SERVICE EQUIPMENT SERVICE LEADLAG X
Load Current Ph1 (U) SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Load Current Ph1 (U) STATUS POWER
Load Current Ph2 (V) SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Load Current Ph2 (V) STATUS POWER
Load Current Ph3 (W) SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Load Current Ph3 (W) STATUS POWER
Loadshed SERVICE CONTROL ALGORITHM STATUS LOADSHED
Loadshed Function SERVICE EQUIPMENT CONFIGURATION NET_OPT
Loadshed Function SERVICE CONTROL ALGORITHM STATUS LOADSHED
Loadshed Timer SERVICE CONTROL ALGORITHM STATUS LOADSHED
LOCAL DEFAULT SCREEN X
Local Network Device SERVICE ATTACH TO NETWORK DEVICE X
Local Time Schedule SCHEDULE OCCP01S X
Local Time Schedule (OCCPC01S) SERVICE EQUIPMENT CONFIGURATION OCCDEFCS X
LOG OUT OF DEVICE SERVICE
Low DC Bus Voltage STATUS VFD_STAT
Low Line Voltage STATUS VFD_STAT
Maximum Loadshed Time SERVICE EQUIPMENT CONFIGURATION NET_OPT X
Minimum Output SERVICE EQUIPMENT SERVICE OPTIONS X
Model Number SERVICE ICVC CONFIGURATION
Motor Amps Not Sensed STATUS VFD_STAT
Motor Current % Imbalance SERVICE VFD CONFIG DATA VFD_CONF X
Motor Current Imbal Time SERVICE VFD CONFIG DATA VFD_CONF X
Motor Current Imbalance STATUS POWER
Motor Current Imbalance STATUS VFD_STAT
Motor Current Imbalance SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Motor Kilowatt Hours STATUS POWER
Motor Kilowatts STATUS POWER
Motor Nameplate Amps SERVICE VFD CONFIG DATA VFD_CONF X
Motor Nameplate kW SERVICE VFD CONFIG DATA VFD_CONF X
Motor Nameplate RPM SERVICE VFD CONFIG DATA VFD_CONF X
Motor Nameplate Voltage SERVICE VFD CONFIG DATA VFD_CONF X
Motor Overload SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Motor Overload STATUS POWER
Motor Overload STATUS VFD_STAT
Motor Power Factor SERVICE CONTROL ALGORITHM STATUS VFD_HIST
Motor Power Factor STATUS POWER
Motor Rated Load Amps SERVICE VFD CONFIG DATA VFD_CONF X
Motor Rated Load kW SERVICE VFD CONFIG DATA VFD_CONF X
OCCPC01S (Local Time Schedule) SCHEDULE OCCP01S X
OCCPC02S (Ice Build Time Schedule) SCHEDULE OCCP02S X
OCCPC03S (CCN Time Schedule) SCHEDULE OCCP03S X
OCCPC01S (Local Time Schedule) SERVICE EQUIPMENT CONFIGURATION OCCDEFCS X
OCCPC02S (Ice Build Time Schedule) SERVICE EQUIPMENT CONFIGURATION OCCDEFCS X
OCCPC03S (CCN Time Schedule) SERVICE EQUIPMENT CONFIGURATION OCCDEFCS X
Occupied? STATUS MAINSTAT
Oil Heater Relay STATUS COMPRESS
Oil Heater Relay Test SERVICE CONTROL TEST DISCRETE OUTPUTS X
Oil Press Verify Time SERVICE EQUIPMENT SERVICE SETUP1 X