Carrier AQUAZONE 50PEC09-18 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes à chaleur Carrier AQUAZONE 50PEC09-18. Carrier AQUAZONE 50PEC09-18 Product data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
© Carrier Corporation 2014 Form 50PEC-1APD
Single-package console water source
heat pump with self-contained line
voltage thermostats.
Suitable for either geothermal or
boiler/tower applications with
operating temperature range from
25 F to 110 F.
Thermostatic expansion valve (TXV)
Rubber grommet mounted
compressors for quiet operation
Sloped top cabinet
Right or left hand piping connection
Multiple unit-mounted and remote
thermostat options
Adaptable cabinet and subbase
configurations
Factory-mounted flow regulators and
control valves for easy installation
Non-ozone depleting Puron
refrigerant (R-410A)
Features/Benefits
Carrier’s Aquazone console
water source heat pumps are
a flexible, attractive
alternative for all finished
interior space, under-window
style installations.
Operating efficiency
Aquazone water source heat pump
(WSHP) units are designed for quality
and performance excellence over their
lifetime. Units offer standard cooling
EERs (energy efficiency ratios) up to
13.3 for boiler/tower systems and as
high as 22.3 for geothermal applica-
tions. Heating COPs (coefficients of
performance) are as high as 4.6,
among the highest in the industry.
Quiet operation
The Carrier console WSHP provides
exceptionally quiet operation for maxi-
mum comfort.
Aquazone™
50PEC09-18
Water Source Heat Pumps Console Unit
with Puron
®
Refrigerant
(R-410A)
*For units purchased on or after June 23, 2014.
3
/
4
to 1
1
/
2
Nominal Tons
Advance
Product
Data*
TM
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Features/Benefits

© Carrier Corporation 2014 Form 50PEC-1APDSingle-package console water source heat pump with self-contained line voltage thermostats.• Suitable for ei

Page 2 - Table of contents

1050PEC12 — COOLING, NOMINAL AIRFLOW 450 CFM, 2.5 GPM50PEC12 — HEATING, NOMINAL AIRFLOW 450 CFM, 2.5 GPM50PEC12 — LOW TEMPERATURE HEATING*, NOMINAL AI

Page 3 - refrigerant (R-410A)

1150PEC15 — COOLING, NOMINAL AIRFLOW 550 CFM, 4.0 GPM50PEC15 — HEATING, NOMINAL AIRFLOW 550 CFM, 4.0 GPM50PEC15 — LOW TEMPERATURE HEATING*, NOMINAL AI

Page 4 - Model number nomenclature

1250PEC18 — COOLING, NOMINAL AIRFLOW 600 CFM, 5.0 GPM50PEC18 — HEATING, NOMINAL AIRFLOW 600 CFM, 5.0 GPM50PEC18 — LOW TEMPERATURE HEATING*, NOMINAL AI

Page 5 - AHRI/ISO capacity ratings

13SOUND DATA — SOUND POWER LEVEL, CASING RADIATED50PEC UNITOCTAVE BAND SOUND POWER LEVELS db, RE 10-12 WATTS125 250 500 1000 2000 4000 8000AHRI Sound

Page 6 - Options and accessories

14Aquazone™ water source heat pump products are availablein a flexible, efficient array of models, which can be used inall types of water loop, ground

Page 7 - Dimensions

15Hybrid systems — In some applications, it may be bene-ficial to incorporate a cooling tower into the ground loopsystem to reduce the overall cost. A

Page 8 - Dimensions (cont)

16WATER QUALITY GUIDELINESLEGEND*Heat exchanger materials considered are copper, cupronickel, 304 SS(stainless steel), 316 SS, titanium.†Closed recirc

Page 9 - Performance data

17WSHP sound controlAnalyzing the projected sound level in the conditionedspace caused by a WSHP unit is quite involved. The key isto have good sound

Page 10 - Performance data (cont)

18LEGEND50PECUNIT SIZEVOLTAGEv-ph-HzCOMPRESSOR BLOWERMIN CIRCUIT AMPSMAX FUSE/HACRQTY FLA HPQTY RLA LRA09115-1-60 1 7.0 45.6 1 2.1 0.10 10.9 15208/230

Page 11

19Console Water Source Heat PumpsHVAC Guide SpecificationsSize Range: 6,220 to 20,760 BtuhCooling Capacity6,810 to 20,160 BtuhHeating CapacityCarrier

Page 12

2Design flexibilityAquazone™ console WSHP units are offered in 4 capacity sizes to meet indi-vidual zone needs efficiently and effec-tively. Standard

Page 13

20mounted on the supply and return waterconnections.3. Unit Controls:Safety devices on all units shall include low-pressure sensor or loss-of-charge s

Page 14 - Application data

217. Optional Controls:a. Units designed for connection to remote wallmounted thermostat shall be wired such thatthe operating controls are at the the

Page 17 - Console units

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Pg 2

Page 18 - Electrical data

3recognizes thirty continuous seconds of overflow as a fault condition.High and low voltage protection — Safety protection for excessive or low voltag

Page 19 - Guide specifications

4Std (No OA Damper)AOA Damper1Standard CleanableMesh FilterModel SeriesModel Series09 – 3/412 – 115 – 11/418 – 11/2L – Standard C Microprocessor Co

Page 20 - Guide specifications (cont)

5LEGEND NOTES:1. Ratings are in accordance with and certified to AHRI/ISO Stan-dard 13256-1.2. Cooling capacities based upon 80.6 F db, 66.2 F wb ente

Page 21

6Factory-wired optionsUnit mounted controller is a factory-wired option. Thestandard unit mounted controller provides a tactile touch-pad for temperat

Page 22

7NOTES: All dimensions within ± 0.125". Filter size: 7" x 30 1/4" x 3/8" Aluminum Mesh LEFT HAND WATERCONNECTIONSRIGHT HAND WATER

Page 23

842.751.3812.0011.008.002.750.7515.633.3813.501.751.002.00WaterOutWaterInCondensateWater19.5613.755.001.63LEFT HAND WATERRIGHT HAND WATER11.008.000.75

Page 24 - Replaces: NEW

950PEC09 — COOLING, NOMINAL AIRFLOW 350 CFM, 2.0 GPM50PEC09 — HEATING, NOMINAL AIRFLOW 350 CFM, 2.0 GPM50PEC09 — LOW TEMPERATURE HEATING*, NOMINAL AIR