Carrier AQUAZONE 50RHC006-060 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes à chaleur Carrier AQUAZONE 50RHC006-060. Carrier AQUAZONE 50RHC006-060 Product data [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Copyright 2004 Carrier Corporation Form 50RHC,RVC-2PD
Single-Package Horizontally and Ver-
tically Mounted Water Source Heat
Pumps with Solid-State Controls.
Compact cabinet design
Performance certified to ARI/ISO/
ASHRAE 13256-1
Waterloop (boiler/tower) application
use with an operating temperature
range of 60 F to 95 F
Simplified refrigeration circuit
provides efficient and reliable
refrigerant flow
Mute package available for quiet
operation
Three service panels for
compressor section for easy
maintenance
Meets new ASHRAE 90.1 per-
formance requirements
Backward compatibility for replac-
ing older Carrier and other
manufacturers’ units
Flexible and reliable controls
accommodate all systems
Features/Benefits
Carrier’s Aquazone™
standard efficiency water
source heat pumps (WSHPs)
are an efficient, compact
alternative for all boiler/tower
and retrofit applications
Operating efficiency
Carrier horizontal and vertical water
source heat pumps are designed for
quality and high performance over a
lifetime of operation. Aquazone
standard efficiency units offer cooling
EERs (energy efficiency ratios) to 13
and heating COPs (coefficients of per-
formance) to 4.6. Efficiency ratings
stated are in accordance with standard
conditions under ARI/ISO/ASHRAE
Standard 13256-1 and provide among
AQUAZONE
50RHC006-060
50RVC009-060
Standard Efficiency
Water Source Heat Pumps
Horizontal —
1
/
2
to 5 Nominal Tons
Ver tical
3
/
4
to 5 Nominal Tons
Product
Data
TM
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - Features/Benefits

Copyright 2004 Carrier Corporation Form 50RHC,RVC-2PDSingle-Package Horizontally and Ver-tically Mounted Water Source HeatPumps with Solid-State Contr

Page 2 - Table of contents

10DimensionsAIRFLOW CONFIGURATIONCode Return DischargeS Left RightE Left BackZ Right LeftB Right Back50RHC006-060 UNITSNOTES:1. Condensate is3/4-in. F

Page 3 - Features/Benefits (cont)

11AIRFLOW CONFIGURATIONCode Return DischargeF Front TopL Left TopR Right Top50RVC009-060 UNITSNOTES:1. Condensate is3/4in. (19.1 mm) FPT.2. Filter bra

Page 4 - Model number nomenclature

12I Determine the actual cooling and heatingloads at the desired dry bulb and wet bulbconditions.Assume cooling load at desired dry bulb 80 F andwet b

Page 5 - ARI/ISO capacity ratings

13VII ARI/ISO/ASHRAE 13256-1 ConversionPerformance standard ARI/ISO/ASHRAE 13256-1became effective on January 1, 2000 and replacedthe existing ARI Sta

Page 6 - Physical data

1450RHC006 — 220 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data points.N

Page 7 - Options and accessories

1550RHC,RVC009 — 325 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poin

Page 8 - CARRIER AQUAZONE THERMOSTATS

1650RHC,RVC012 — 400 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poin

Page 9

1750RHC,RVC018 — 600 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poin

Page 10 - Dimensions

1850RHC,RVC024 — 800 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poin

Page 11 - VERTICAL DIMENSIONAL DATA

1950RHC,RVC030 — 1000 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poi

Page 12

2the highest ratings in the industry,exceeding ASHRAE (American Society of Heating, Refrigerant and AirConditioning Engineers) 90.1 Energy Standards.H

Page 13

2050RHC,RVC036 — 1200 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poi

Page 14 - Performance data

2150RVC041 — 1325 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data points.

Page 15

2250RHC,RVC042 — 1350 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poi

Page 16 - Performance data (cont)

2350RHC,RVC048 — 1600 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poi

Page 17

2450RHC,RVC060 — 2000 CFM NOMINAL AIRFLOWLEGEND*ARI 320 points (bold printing) are shown for comparison purposesonly. These are not certified data poi

Page 18

25AIRFLOW CORRECTION TABLELEGENDNOTE: 400 cfm is nominal airflow.ENTERING AIR CORRECTION TABLESLEGEND*Sensible capacity equals total capacity.NOTES:1.

Page 19

2650RHC,RVC BLOWER PERFORMANCE*Size 006 available in 50RHC unit only.†Size 041 available in 50RVC unit only.NOTES:1. Gray areas denote ESP (external s

Page 20

27→ OCTAVE BAND SOUND POWER LEVEL (dB re 1 pW) STANDARD UNIT*Size 006 available in 50RHC unit only.NOTES:1. All performance is Sound Power Level in dB

Page 21

28OCTAVE BAND SOUND POWER LEVEL (dB re 1pW) MUTE CONSTRUCTION*Size 006 available in 50RHC unit only.NOTES:1. All performance is Sound Power Level in d

Page 22

2950RHC,RVC ELECTRICAL DATALEGEND*Size 006 available in 50RHR unit only.†Size 041 available in 50RVC unit only.NOTES:1. HACR circuit breaker in U.S.A.

Page 23

3 All components are carefully de-signed and selected for endurance, durability, and carefree day-to-dayoperation. The Aquazone™ unit is shipped t

Page 24

30Typical piping and wiringReturnAirPowerThermostatWiringCompressorAccess PanelBalancing Valve(field-installedand calibratedaccessory)Field-suppliedst

Page 25 - AIRFLOW CORRECTION TABLE

31Typial wiring schematics*Optional wiring.AL — Alarm Relay ContactsBM — Blower MotorBMC — Blower Motor CapacitorBR — Blower RelayCAP — CapacitorCB —

Page 26

32Typical wiring schematics (cont)AL — Alarm Relay ContactsBM — Blower MotorBMC — Blower Motor CapacitorCAP — CapacitorCB — Circuit BreakerCC — Compre

Page 27

33Typical control wiringYWOGRCAL1AL2ACRCMP1FANPWRHS1/EXH/RVSPREMIERLINKCRCOMPLETECCONTROLJ4J6J5J8J1PWRSPSALWCMPSAFETTTY1GRCAL1CMP1FANPWRPREMIERLINKDEL

Page 28

34Aquazone™ water source heat pumps are available in aflexible, efficient array of models, which can be used in alltypes of water loop, ground water,

Page 29 - Electrical data

352. Corrosion is caused by absorption of gases from theair coupled with water on exposed metal. Corrosionis also common in salt-water areas.3. Organi

Page 30 - Typical piping and wiring

364. Provide an acoustical pad underneath the WSHP unitin applications where the unit must be mountedabove noise sensitive areas such as private offic

Page 31 - Typial wiring schematics

37TYPICAL UNIT OPERATING PRESSURES AND TEMPERATURES*Cooling air and water numbers can vary greatly with changes in humidity.†Subcooling is based upon

Page 32

38Packaged Water Source Heat PumpsHVAC Guide SpecificationsSize Range: 6,400 to 58,000 BtuhCooling Capacity8,300 to 76,800 BtuhHeating CapacityCarrier

Page 33 - Typical control wiring

395. Cfm/Static pressure rating of the unit shall bebased on a dry coil and a clean filter in place.D. Refrigerant Components:1. Units shall have a se

Page 34 - Application data

4Carrier PremierLink™ control-ler adds reliability, efficiency, and simplificationThe PremierLink direct digital control-ler can be ordered as a facto

Page 35 - Horizontal units

40electronic). The control system microprocessorboard shall be specifically designed to protectagainst building electrical system noise contami-nation

Page 36 - Application data (cont)

415-minute built-in compressor protection, lock-ing cover included.2. Loop Controller with six stages (2 stages forheating and 4 stages for heat rejec

Page 39

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.New

Page 40 - Guide specifications (cont)

5LEGENDNOTES:1. A water-to-air heat pump using water or brine circulating in a common pipingloop functioning as a heat source/heat sink.2. The tempera

Page 41

6PHYSICAL DATA — AQUAZONE™ 50RHC,RVC006-060 UNITSLEGENDPSC — Permanent Split Capacitor*Size 006 available in 50RHR unit only.†Size 041 available in 50

Page 42

7Factory-installed optionsCupronickel heat exchangers are available for highercorrosion protection for applications such as open tower,geothermal, etc

Page 43

8Y strainers (bronze body) are “Y” type strainers with abrass cap. Maximum operating pressure rating of400 psi. Strainer screen made of stainless st

Page 44

9PREMIERLINK™ COMMUNICATING CONTROL

Commentaires sur ces manuels

Pas de commentaire