Copyright 2005 Carrier Corporation Form 50AH-7PD
The 50AH single-package cooling
units feature:
compact design
flexibility
easy maintenance
high quality and reliability
quiet and efficient scroll compressor
technology
Features/Benefits
All in one package — high
cooling efficiency, instal-
lation convenience, ease of
accessibility allow for time-
saving maintenance.
Space and cost saving design
The Carrier 50AH Roomtop unit is spe-
cifically designed to provide building
owners with truly out-of-sight cooling.
The compact design and low silhouette
enable it to fit easily and securely within
the ceiling above the conditioned space.
Single-package construction makes it
easy to install with minimal time and
cost.
Application flexibility
If desired for particular applications, the
unit can also be installed as a split system
with the condenser section mounted hor-
izontally. Centrifugal fans permit ducting
of both evaporator and condenser air.
Quiet operation
Commercial end users appreciate the
extra comfort of quiet operation. Carrier
engineers met the challenge by specify-
ing heavy insulation, vibration-resistant
construction and operating components
that function at low noise levels, all of
which keep system sound at a minimum
level.
ROOMTOP®
50AH
Horizontal Indoor
Single-Package
Cooling Units
3to5NominalTons
Product
Data
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Features/Benefits

Copyright 2005 Carrier Corporation Form 50AH-7PDThe 50AH single-package coolingunits feature:• compact design• flexibility• easy maintenance• high qua

Page 2 - Table of contents

10CONDENSER FAN PERFORMANCELEGENDNOTES:1. Above fan performance is based upon coil and deducted casing lossesonly.2. External static pressure (ESP) is

Page 3 - Model number nomenclature

11LEGEND*Optional evaporator-fan motor nameplate data.ELECTRIC HEATER DATALEGEND*May be field converted to single-phase units, see electric heat insta

Page 4 - Physical data

12Typical wiring schematic50AH036,048,060 — 208/230-3-60 UNITSLEGENDAHA — Adjustable Heat AnticipatorC—Contactor CompressorCB — Circuit BreakerCC — Co

Page 5 - Field-installed accessories

13Application dataOUTDOOR-AIR TEMPERATURE OPERATING LIMITS (F)Field splitting instructions — If components are split,maximum length of refrigerant tub

Page 6 - Dimensions

14Indoor Packaged UnitHVAC Guide Specifications — Section 15787Size Range: 3 to 5 Tons, NominalCarrier Model Number: 50AHPart 1 — General1.01 SYSTEM D

Page 7

15J. Electrical Requirements:Unit shall have single point power connection toleads in terminal box.K. Special Features:Certain standard features are n

Page 8 - Performance data

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.New

Page 9 - EVAPORATOR FAN PERFORMANCE

2Easy maintenanceWhen it comes to maintenance, the 50AH rates high in accessibility. Indoor location is ideal for the maintenance technician, and five

Page 10 - Performance data (cont)

3ARI* capacity ratingsLEGEND*Air-conditioning and Refrigeration Institute.NOTES:1. Ratings are at zero condenser air static and rated in accordance wi

Page 11 - Electrical data

4LEGEND*Shipping weights include base unit plus packaging.†If components are to be split, additional refrigerant will be needed.**Two-speed motor.††Us

Page 12 - Typical wiring schematic

5Thermostat and subbase — Attractive wall-mounted24-v accessory provides precise temperature control.Automatic and manual changeover models available.

Page 13 - Typical piping and wiring

6DimensionsLEFT SIDERIGHT SIDEDIMENSIONS (ft-in.)UNIT50AHABCDE036 2-43/42-2 1- 53/41-2 1-10482-5 2-3 1-115/81-87/81-77/80602-43/42-23/41-115/81-87/81-

Page 14 - Guide specifications

7I Determine cooling requirements at designconditions.Given:Gross Cooling CapacityRequired (TC) . . . . . . . . . . . . . . . . . .39,000 BtuhSensible

Page 15

8GROSS COOLING CAPACITIESLEGENDNOTES:1. Performance based on nominal condenser airflow listed in physical data tableon page 4.2. SHC is based on 80 F

Page 16

9EVAPORATOR FAN PERFORMANCELEGEND*Standard direct drive indoor (evaporator) fan motor (IFM). For optionalbelt drive IFM performance, see table below.N