Carrier PERFORMANCETSERIES EDGER THERMIDISTATT CONTROL TP-NRH-A Manuel d'instructions Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 84
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
14
2. Route wires through large hole in mounting base. Level mounting base
against wall (for aesthetic value only—Display Module need not be lev-
eled for proper operation) and mark wall through 2 mounting holes. See
Fig. 6.
A07165
Fig. 6 -- Backplate Mounting
3. Drill two 3/16 --in. mounting holes in wall where marked. Thermidistat
Control may be mounted to a standard junction box, if desired. Hole pat-
tern on Thermidistat Control mounting base matches junction box mount-
ing holes.
4. Secure rear plastic mounting base to wall with 2 screws and anchors pro-
vided. Additional mounting holes are available for more secure mounting
if needed. Make sure all wires extend through hole in mounting base.
5. Adjust length and routing of each wire to reach proper connector block
and terminal on mounting base with 1/4--in. extra wire.
Vue de la page 13