37
SERVICE SCHEDULE FOR SUPRA 950
Petroleum and
Synthetic Oil -
Without Bypass
At 250 Hours
D Check engine cooling system.
D Check and clean the air filter.
D Check all bolts, screws and unit mounting bolts
for tightness. Tighten as required.
D Check all belts.
Petroleum Oil
Without Bypass
At 1000 and ev-
ery 1000 hours
after
Synthetic Oil -
Without Bypass
At 1500, 3000
and 4000 hours
D Replace lube oil and filter.
D Check engine cooling system.
D Check and clean the air filter.
D Check all belts.
Petroleum and
Synthetic Oil
Without Bypass
At 1500 Hours
D Check fuel pump filter.
D Replace the cartridge of the dry air filter.
D Check battery terminals and fluid level.
D Check compressor oil level. Use polyol ester
oil (POE) approved by CARRIER.
D Check alternator brushes. Check for diesel and
standby hours.
D Check engine thermostat.
D Check defrost:
-- Check timer setting and function
-- Check refrigerant control valves
-- Fans stop or defrost damper closes
-- Defrost ends automatically
-- Water drains from evaporator
D Check fan motor brushes.
D Check and adjust rocker arms.
D Check belts as necessary.
Petroleum and
Synthetic Oil
Without Bypass
At 2000 Hours
D Replace oil filter.
D Clean radiator/condenser coil.
D Check refrigerant level.
Petroleum and
Synthetic Oil
Without Bypass
At 3000 Hours
D Change fan motor brushes.
D Check and rebuild alternator.
D
Check engine speed:
High -- 2300 to 2350
Low -- 1800 to 1850