Carrier 38TDB Guide de dépannage Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 22
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
Software Revs 3,5,6,8,10, 12 Infinity /Evolution Troubleshooting (Rev. 2)
10-12-2006
20
Before condemning the User Interface or circuit board
Re-install the system:
In some situations, there may have been changes and additions to the system set up after initial
installation. This can cause problems because the system has not been “told” of the changes,
and it does not recognize them. Cycling power does not tell the system a new component
has been installed. Follow the steps below:
-Push and hold Advance for 10 seconds
-Install
Follow screen prompts
Reset Factory Defaults:
This will put you back to the beginning and could avoid confusion from unknown changes to the
system configuration. Follow steps below:
•Push and hold Advance for 10 seconds
•Setup
Thermostat
Reset Factory Default
Program Schedule-YES
User Settings- YES
Install Settings- YES
Last 10 Faults – YES
Changing components
If a circuit board is changed, remember that the fault history is maintained in the User Interface Last 10
System Events. Faults from the previous failed components will remain in the history unless cleared.
Vue de la page 19
1 2 ... 15 16 17 18 19 20 21 22

Commentaires sur ces manuels

Pas de commentaire