GB - 8
In case of…
If the unit appears not to be operating
correctly, before calling a service
technician please check that...
... the operating instructions in the
literature have been followed.
... the main switch is switched on, that
the power supply is not interrupted and
that the unit is correctly plugged in.
... the filters are not dirty.
... the water collection tank is correctly
inserted in its position.
If the unit is not used for extended
periods:
Empty the remaining condensate
water through the drain tube at the
back of the unit.
Clean the filters.
Hung the outdoor unit on the back of
the indoor unit.
Cover the air conditioner
...use of quick-connect
couplings for fixed installation.
Models 51AKC009 and 51AKC012
are provided with quick coupling
connections that allow the units to
be disconnected up to a maximum
of six times without impairing the
performance of the air conditioner.
This operation must always be
carried out by qualified and
authorized personnel.
To disconnect proceed as
follows:
Switch the unit off, turning the mode
selector counterclockwise to symbol
and remove the plug from the power
supply socket.
Using the special tool, unscrew the
fixing screw and remove the closing
cover.
Disconnect the electrical connector.
Loosen the fixing clamp of the small
tube that takes condensing water to the
outdoor unit, taking care to discharge
the remaining condensate water into a
pan or the indoor unit collection tank.
With a screwdriver, unscrew partially the 4 screws of the
fixing bracket flexible pipe.
Using two fixed wrenches (24 mm on turning nut and 19 or
21 mm on fixed parts) operate on the turning nut, unscrew
and remove the quick coupling connections.
Remove the 4 screws of the fixing bracket flexible pipe.
Protect the connection end parts with caps. Position the
outdoor unit outside in the desired position passing the
flexible pipe through the hole (Ø 60 mm) in the wall.
The two parts of the air conditioner should remain split for the
shortest possible time.
For unit re-assembling repeat the previous operations in
reverse order.
For re-connection of the quick coupling, apply a tightening
torque of 23 to 27 Nm.