AUTOMATIC START UP IN DIESEL WHEN LOSS OF STANDBY
FROM EPROM 3.19 FOR MONO TEMP
FROM
EPROM 4.05 FOR MULTI TEMP
NOTE : This option must be configured in service centre according to customer request.
To activate this function: TIME STRT set up in functional parameters.
When the unit is started in standby, the "ROAD" light is flashing and the "STANDBY" light is lit.
After 5 minutes of loss of power, the unit automatically starts in diesel
. 5 minutes after the power comes
back, the unit starts again automatically in electric mode. The "STANDBY MOTOR" alarm appears, alarm that
you would have to clear.
* This function will be active even after a stop (OFF) of the unit. To deactivate it: set up TEMP STRT in
functional parameters.
DEACTIVATE THIS FUNCTION WHEN UNIT IS RUNNING IN A CLOSED AREA !
NOTE : For MONO TEMP – from EPROM 3.23
To be available, this option must be previously configured in Service Center according to customer request.
Belts and fans :
This refrigeration unit is equipped with Auto-start/stop, it may start at any time
and without warning.
When the unit is running beware of belts and fans that are moving. Before servicing refrigeration unit,
make sure the main power switch is on the OFF position.
Ensure the unit will not restart. Lock-out / Tag-out can be performed as described above.
When there is protective structure (fan grid or guard for example) make sure they are in place. Never
removed them when the refrigeration unit is running.
Always keep your hands, body parts, clothes, hairs and tools far from moving parts.
6