Carrier TP -NRH Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Thermostats Carrier TP -NRH. Carrier TP -NRH Instruction manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Installation Instructions

TP--WEM01Carrierr Côr™ ThermostatAC/HP Wi-Fir ThermostatPerformance™ SeriesInstallation InstructionsA14493NOTE: Read the entire instruction manual bef

Page 2

7Items Included In Box (Cont.)A14496Fig. 3 -- Large BackplateA14497Fig. 4 -- Screws and Anchors

Page 3 - TABLE OF CONTENTS

8Items Included In Box (Cont.) A14498Fig. 5 -- Installation Instruction, Quick Start Guide, and Wire LabelsItems You Will NeedA. Phillips screwdriver

Page 4 - SAFETY CONSIDERATIONS

9Step 1. Power Off the HVAC SystemELECTRICAL OPERATION HAZARDFailure to follow this warning could result in injury or death.Before installing thermost

Page 5 - INSTALLATION CONSIDERATIONS

10Step 2. Remove Existing ThermostatRemove the cover from your old thermostat. Most snap off easily butsome may be attached by screws.Note: If the old

Page 6 - INSTALLATION

11Discard any jumper wires between Rh, Rc, or R. This thermostat doesnot need them. They are jumpered internally.When done, remove the old thermostat

Page 7 - Compatible Systems

12Installing the optional large backplateIf the small backplate doesn’t cover the marks left by the previousthermostat, attach the larger backplate in

Page 8 - Terminal Descriptions

13A14500Fig. 7 -- Secure Backplate to Wall

Page 9 - Items Included In Box

14Step 4. Connect the WiringThe wires from the wall should plug easily into the terminal blocks.Adjust length and routing of each wire to reach proper

Page 10 - Items Included In Box (Cont.)

15RcGY1W1(AUX1)O/BA14501Fig. 8 -- Terminal Block Release LeverELECTRICAL OPERATION HAZARDFailure to follow this warning could result in injury or deat

Page 11 - Before You Start

16System wiring diagrams covered are:d Conventional heating and cooling systemsd Heat pumps (air or geothermal)d Boilers or radiant heat systemsd Acce

Page 13

17TROUBLESHOOTINGIf your thermostat does not power on, please check the following:1. Check that all wires are properly inserted into the terminal bloc

Page 14

18WIRING DIAGRAMSThe following pages provide wiring diagrams for common HVACequipment configurations.Single Stage Cooling and Heating SystemACYCFurnac

Page 15 - Secure the backplate

19WIRING DIAGRAMS (Cont.)FurnaceTwo Stage Cooling and/or Heating SystemACY1 Y2CFurnaceY1Y/Y2W1 W2 R C GRcGY/Y1W/W1(AUX1)O/BACC–ACC+W2(AUX2)Y2CRHRA1450

Page 16

20WIRING DIAGRAMS (Cont.)Heat PumpFan Coil or FurnaceSingle Stage Heat Pump and Auxiliary Heat W2O/BYRCWO/B*YGRCRcGY/Y1W/W1(AUX1)O/BACC–ACC+W2(AUX2)Y2

Page 17 - Step 4. Connect the Wiring

21WIRING DIAGRAMS (Cont.)Heat PumpFan Coil or FurnacesStage 2 Heat Pump and Auxiliary Heat W2W1O/B Y1 Y2 R C W1O/B* W2 Y1 GY/Y2 R CRcGY/Y1W/W1(AUX1)O/

Page 18

22WIRING DIAGRAMS (Cont.)Air Conditioneror Heat PumpBoilerStage 2 Heat and Cool (If Applicable)*Reversing Valve for Heat Pumps OnlyRcGY/Y1W/W1(AUX1)O/

Page 19 - Congratulations, you’re done!

23WIRING DIAGRAMS (Cont.)Accessory DevicesThe thermostat can control an accessory HVAC device like ahumidifier, dehumidifier, or ventilation device fr

Page 20 - FEATURES

24ApprovalsThis product was designed and built in accordance to RoHS directive2002/95/EC and contains no hazardous substances as defined by thisdirect

Page 21 - WIRING DIAGRAMS

25d Connect the equipment into an outlet on a circuit different fromthat to which the receiver is connected.d Consult the dealer or an experienced rad

Page 22 - WIRING DIAGRAMS (Cont.)

262. this device must accept any interference, including interferencethat may cause undesired operation of the device.Le présent appareil est conforme

Page 23 - Fan Coil or Furnace

TABLE OF CONTENTSPAGESAFETY CONSIDERATIONS 1...INTRODUCTION 2...INSTALLATION CON

Page 26

www.Carrier.com/myhome S 1--800--CARRIERCopyright 2014 Ca rrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231Edition Date: 10/14Manufacturer res

Page 27 - Approvals

1SAFETY CONSIDERATIONSRead and follow manufacturer instructions carefully. Follow all localelectrical codes during installation. All wiring must confo

Page 28 - Compliance Notice:

2INTRODUCTIONThe Carrierr Côrt thermostat is a wall--mounted, low--voltagethermostat which maintains room temperature by controlling theoperation of a

Page 29

3INSTALLATIONInstallation Notes:d The maximum wire size to be used in the installation is22AWG (0.50mm2) with 0.8mm insulationd No part of the control

Page 30

4d Close to or in direct airflow from supply registers and return--air registers.d In areas with poor air circulation, such as behind a door or inan a

Page 31

5Terminal DescriptionsG FanRc Cool transformerRh Heat transformerO/B Heat pump reversing valveY/Y1 Used for first stage of conventional A/C or firstst

Page 32 - Edition Date: 10/14

6Items Included In BoxA14494Fig. 1 -- Carrier Côrr ThermostatA14495Fig. 2 -- Small BackplateNOTE: The Mounting Plate (center) is removable for both ba