Carrier 48/50PD05 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Climatiseurs à système divisé Carrier 48/50PD05. Carrier 48/50PD05 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 11
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
HH57AC078
CRENTDIF004A00
Installation Instructions
ROOFTOP UNITS, 2 to 25 TONS
ACCESSORYENTHALPYSENSORAND
DIFFERENTIAL ENTHALPY SENSOR FOR
ECONOMI$ERt IV
TABLE OF CONTENTS
PACKAGE CONTENTS -- HH57AC078 1............
PACKAGE CONTENTS -- CRENTDIF004A00 1......
SAFETY CONSIDERATIONS 2....................
GENERAL 2....................................
Outdoor Enthalpy Changeover Control 2..................
Differential Enthalpy Control 2..........................
INSTALLATION 3...............................
Single Outdoor Air Enthalpy Sensor 3--6..................
Differential Enthalpy Sensor 7--10.......................
CONFIGURATION 11............................
Outdoor Enthalpy Changeover Control 11.................
Differential Enthalpy Control 11.........................
IMPORTANT: Read these instructions completely before
attempting to install the accessory enthalpy sensor.
PACKAGE CONTENTS --
HH57AC078
QTY CONTENTS
1 Enthalpy Sensor
CRENTDIF004A00
QTY CONTENTS
1 Enthalpy Sensor
2 6---20, 3/4 in. Sheet Metal Screw
1 Grommet
1 Black Wire
1 Red Wire
The HH57AC078 and CRENTDIF004A00 enthalpy
sensors are used with the Economi$er IV (part numbers
CRECOMZR008C00, 020A02, 021A03, 024A02,
025A02, 038A00, 039A00, 040A00, 041A00, 042A00,
046A00, 047A00, 050A00, 051A00, 056A00, 057A00,
062A00, 064A00) and are used on the following units:
UNIT SIZE UNIT SIZE
48HE 003---006 542J 150, 180
50HE 003---006 548F 036---120
50HEQ 003---006 549B 036---120
48HJ 004---028 549C 024---060
50HJ 004---028 551A 155---300
50HJQ 004---016 551B 036 ---150
48PD 05---06 551C 024 --- 060
50PD 05---06 558F 036 ---300
48PG 03---28 558J 04---16
50PG 03---28 559F 180---300
48PM 20---28 579F 180 ---300
50PM 20---28 580F 036 ---300
48TC 04---16 580J 04 ---16
50TC 04---16 581A 155 ---300
48TF 004 ---014 581B 036--- 150
50TFF 004---014 581C 024---060
50TCQ 04---14 548J 04---14
48HC 04---14 581J 04---14
50HC 04---14 551J 04---14
50HCQ 04---12 549J 04---12
50TFQ 004---012
48TJ
016---028
50TJ
016---028
48TM
004---028
50TM
004---028
The accessory enthalpy sensor can be used on all rooftop
units with a factory--installed or accessory Economi$er IV.
Copyright 2011 CAC / BDP D 7310 W. Mo rris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 3/11
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No:IIK---HH57CRENT--- 03
R e p l a c e s : I I K --- H H 5 7 C R E N T --- 0 2
Vue de la page 0
1 2 3 4 5 6 ... 10 11

Résumé du contenu

Page 1 - Installation Instructions

HH57AC078CRENTDIF004A00Installation InstructionsROOFTOP UNITS, 2 to 25 TONSACCESSORYENTHALPYSENSORANDDIFFERENTIAL ENTHALPY SENSOR FORECONOMI$ERt IVTAB

Page 2 - SAFETY CONSIDERATIONS

10Differential Enthalpy Sensor InstallationInstructions for 48/50HJ015--017,50HJQ014--016, 48/50TJ,TM016--028,542J150--180, 551A/581A155--180,558F/559

Page 3 - INSTALLATION

11CONFIGURATIONOutdoor Enthalpy Changeover ControlWhen the outdoor air enthalpy rises above the adjustablefree cooling/enthalpy changeover set point,

Page 4 - 551A/581A210--300 Units

2Table1–Economi$erIVSensorUsageAPPLICATIONEconomi$er IV WITH OUTDOOR AIR DRY BULB SENSORAccessories RequiredOutdoor Air Dry BulbNone. The outdoor air

Page 5

3INSTALLATIONNOTE: The 48/50PD, PG, PM, TC, TCQ, HC, HCQ,558J, 580J, 548J, 581J, 551J and 549J units have a choiceof dry--bulb or enthalpy sensor with

Page 6

4Single Outdoor Air Enthalpy SensorInstallation for 48/50PG20--28,48/50PM20--28, 48/50HJ020--028 and551A/581A210--300 Units1. Turn off power to unit a

Page 7 - 48/50PG03--16 Units

5Single Outdoor Air Enthalpy SensorInstallation for 48/50TC04--16, 48/50HC04--14,50TCQ04--14, 50HCQ04--1248/50HE,TF,TM003--014, 48/50HJ004--014,50HEQ,

Page 8 - 48/50PG20--28, 48/50PM20--28

6Single Outdoor Air Enthalpy SensorInstallation for 48/50HJ015--017,50HJQ014--016, 48/50TJ,TM016--028,542J150--180, 551A/581A155--180,558F/559F/579F/5

Page 9

7Differential Enthalpy SensorIf installing the differential enthalpy sensor on anaccessory Economi$er, it is easier to install the differentialenthalp

Page 10

8Differential Enthalpy Sensor Installation for48/50PG20--28, 48/50PM20--28,48/50HJ020--028, and 551A/581A210--300Units1. Turn off power to unit and in

Page 11 - Differential Enthalpy Control

9Differential Enthalpy Sensor InstallationInstructions for 48/50TC04--16,48/50HC04--14, 50TCQ04--14, 50HCQ04--12,48/50HE,TF,TM003--014, 48/50HJ004--01

Commentaires sur ces manuels

Pas de commentaire