Software Revs 3,5,6,8,10, 12 Infinity /Evolution Troubleshooting (Rev. 2)
10-12-2006
10
User Interface Generated Fault Descriptions cntd.
Fault Description User Interface Display Action
Original
Models
-A models
SAM radio test failed Not applicable to
original models
SAM RADIO
TEST FAILED
Radio not able to access Skytel satellite. Ensure
full coverage is available by checking Skytel web
site. If available, try another location closer to
outside wall.
SAM profile failed Not applicable to
original models
SAM PROFILE
FAILED
SAM not able to communicate equipment profile
to Skytel satellite
Frozen coil detected Not applicable to
original models
POSSIBLE
FROZEN COIL in
fault history.
SYSTEM
MALFUNCTION
on main screen
Static pressure change related to frozen coil
detected. Unit will shut down outdoor unit and run
indoor fan at low speed for 1 hour. Cooling will
then resume if call exsists
Utility Curtailment Not applicable to
original models
UTILITY
CURTAILMENT
EVENT in fault
history
CURTAILMENT
ACTIVE on main
screen
Utility relay in outdoor unit has opened from utility
signal.
Or Utility Saver option has been enabled in the
Setup menu, but utility relay has not been
installed or is wired incorrectly.
Check for proper Utility Relay wiring, if no relay is
installed, enter Setup menu and disable Utility
Saver option.
16 (Zone Board status
light)
User Interface not
communicating with
Zone board
No display in fault history or on main
screen
Zone board not communicating with UI. Possibly
added after initial power up. Re-install the system,
check wiring between user interface and zone
board. Need sensor connected to at least 2
zones.