24ANA
Infinityt Series Air Conditioners
with Puronr Refrigerant
2to5NominalTons(Sizes24to60)
Installation Instructions
NOTE: Read the entire instruction manual before starting the
installation.
Unless otherwise noted, information in these installation
instructions pertain to both 2
4ANA1 and 24ANA7 series units.
Information that is unique to the 24ANA1 series will be identified
as such; likewise information that is unique to the 24ANA7 series
will also be identified.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions included in
literature and attached to the unit. Consult local building codes and
current editions of the National Electrical Code (NEC) NFPA 70.
In Canada, refer to current editions of the Canadian electrical code
CSA 22.1.
Recognize safety information. This is the safety --alert symbol
!
!
.
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand these signal words; DANGER, WARNING, and
CAUTION. These words are used with the safety--alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which ma y result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when handling
parts.
CAUTION
!
Indoor Thermostat Control Options
Model
Infinity
Control
Standard 2 ---stage
Thermostat
24ANA7 Ye s Ye s
24ANA1 Ye s Ye s *
* Units containing circuit board HK38EA015 or newer.
!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position.
There may be more than 1 disconnect switch. Lock out and
tag switch with a suitable warning label.
!
WARNING
UNIT OPERATION AND SAFETY HAZARD
Failure to follow this warning could result in personal injury,
death and/or equipment damage.
Puron refrigerant systems operate at higher pressures than
standard R -- 22 systems. Do not use R-- 22 service equipment
or components on Puron equipment.
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Installation Instructions

24ANAInfinityt Series Air Conditionerswith Puronr Refrigerant2to5NominalTons(Sizes24to60)Installation InstructionsNOTE: Read the entire instruction ma

Page 2 - INSTALLATION

10The control is shipped with the brownout active. The change instatus is remembered until toggled to a new status. A powerdown/power up sequence will

Page 3 - Make Piping Connections

11Table5–2---StageCompressor(Winding Resistance at 70_F ± 20_ / 21.11_C ± 11.11_C)Winding 24ANA724 24ANA736 24ANA748 24ANA760S t a r t ( S --- C ) 2.7

Page 4 - Sweat Connection

12OAT Thermistor must be locked inplace with spherical nib end facing to-wards the front of the control boxFig. 8 -- Outdoor Air Thermistor (OAT) Atta

Page 5 - Install Accessories

13Status CodesTable 6 shows the status codes flashed by the amber status light.Most system problems can be diagnosed by reading the status codeas flas

Page 6 - START--UP

14A08060A08057E d g e T h e r m i d is ta t M o d e l s T P --- P RH --- 0 1 & T P --- N R H --- 0 1w/ Fan Coil & 2 ---Stage Air ConditionerE

Page 7 - SUPPLIED BY UTILITY PROVIDER

15DCBAUser InterfaceDCBADCBAFan CoilCommunicating AC//HPOATRYOWCHUMCHumidifier24vacA03076Fig. 11 -- Infinity Furnace or Fan Coil Wiring with Communica

Page 8 - (OAT>104_F/40_C)

16Copyright 2009 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 07/09Manufacturer reserves the right to c

Page 9 - TROUBLESHOOTING

2INSTALLATION RECOMMENDATIONSNOTE: In some cases noise in the living area has been traced togas pulsations from improper installation of equipment.1.

Page 10

3On rooftop applications, locate unit at least 6 in. (152.4 mm) aboveroof surface.Operating AmbientThe minimum outdoor operating ambient in cooling mo

Page 11 - THERMISTOR CURVE

4Table 2 – Accessory UsageAccessoryREQUIRED FORL O W --- A M B I E N T C O O L I N GAPPLICATIONS(Below 55°F/12.8_C)REQUIRED FOR LONG LINEAPPLICATIONS*

Page 12 - CARE AND MAINTENANCE

5Refrigerant tubes and indoor coil should be evacuated using therecommended deep vacuum method of 500 microns. The alternatetriple evacuation method m

Page 13 - Status Codes

6Make Airflow SelectionsAirflow Setup for Infinity Control Furnace of FE Fancoil(communicating)When using an Infinity User Interface, airflow isautoma

Page 14 - Thermidistat

7System Functions And Sequence Of OperationThe outdoor unit control system has special functions. Thefollowing is an overview of the 2--stage control

Page 15 - RYOWCHUM

8Compressor Operation on 24ANA1 ModelsThe basic scroll design has been modified with the addition of aninternal unloading mechanism that opens a by--p

Page 16 - Catalog No: 24ANA---6SI

9Check ChargeAll 24ANA units must be charged in high stage only.Factory charge amount and desired subcooling are shown on unitrating plate. Charging m