Carrier COMFORTLINK P5030-100 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Grilles Carrier COMFORTLINK P5030-100. Carrier COMFORTLINK P5030-100 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53480054-01 Printed in U.S.A. Form 48P-1SO Pg 1 4-09 Replaces: New
User’s Information Manual
NOTE TO INSTALLER:
This manual should be left with the equipment owner.
Your combination heating/cooling rooftop unit is equipped
with an automatic direct spark ignition system and induced-
draft power combustion blower.
TO LIGHT UNIT
See Fig. 1 for location of gas valve(s). Refer to Fig. 2 while
proceeding with the following steps.
1. Turn off the unit demand for cooling or heating by using
the scrolling marquee. The scrolling marquee is located in
the control box at the compressor end of the unit.
a. Push the key unit a blank display screen
is shown.
b. Push the key until the SERVICE TEST LED is
lit.
c. Push the key. The display will show
STOP.
d. Push the key again. The NO/YES display
will flash.
e. Push the or key to toggle the display to
YES and then push . The unit will be
locked off from heating, cooling or any operation.
The controls will still function and the display will
still operate.
2. Close the field-installed manual gas shutoff valve.
3. Turn off the electrical power to the unit using the optional
disconnect or the field-installed disconnect and lock off
using proper lockout and tag-out procedures.
4. Open the burner section hinged access door.
5. Move the switch on the gas valves to the OFF position
and wait 5 minutes.
NOTE: If this is the first installation of the unit, the gas
flue hoods must be installed before operating unit. These
must be installed for the unit to run properly.
6. Move the switch on the gas valves to the ON position.
7. Close the burner section hinged access door.
8. Turn on the electrical supply to the units.
9. Open the field-installed manual gas valve.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
WARNING
Improper installation, adjustment, alteration, ser-
vice or maintenance can cause injury or property
damage. Refer to this manual. For assistance or
additional information consult a qualified installer,
service agency, or the gas supplier.
WARNING
Before performing recommended maintenance, be sure
main power switch to unit is turned off and lockout tag is
installed. Electrical shock could cause personal injury.
WARNING
Burners will light automatically. Do not attempt to light by
hand; personal injury may result.
DANGER
1. Do not turn off the electrical power to unit without
first turning off the gas supply.
2. Before attempting to start the gas heating section,
familiarize yourself with all the procedures that must
be followed.
3. Never attempt to manually light the burners on the
unit with a match, lighter, or any other flame. If the
electric sparking device fails to light the burners, refer
to the shutdown procedures, then call your dealer as
soon as possible.
If you do not follow these instructions exactly, a fire or
explosion may result, causing property damage, injury, or
loss of life.
ESCAPE
ENTER
ENTER
ENTER
48P2,P3,P4,P5030-100
Gas Heating/Electric Cooling Units
with COMFORTLINK™ Controls
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - User’s Information Manual

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Cata

Page 2 - 055-100 SIZES HIGH HEAT

210. Using the scrolling marquee, enable the unit to run usingthe following procedure:a. Push the key unit a blank display screenis shown.b. Push th

Page 3 - Fig. 2 — To Light Unit

3STEP 1Fig. 2 — To Light UnitSTEP 5STEP 4STEP 3STEP 2STEP 7STEP 6STEP 10STEP 8LOCK-OUTTAGONOFFMAINSTEP 9Run StatusService TestTemperaturePressuresSetp

Page 4

4TO SHUT UNIT OFFSee Fig. 1 for location of gas valve(s). Refer to Fig. 3 whileproceeding with the following steps.1. Turn off the unit demand for coo

Page 5 - LOCK-OUT

5When replacing your unit filters, always use the same sizeand type of filter that was originally supplied by the installer.Units with outdoor air cap

Page 6 - Fig. 4 — Door Locations

6POWEREXHAUSTOPTIONPOWER EXHAUSTACCESS DOOR(TYP BOTH SIDES)FILTERACCESSDOORACCESSDOORSGAS SECTIONACCESS DOORGASBURNERSAIRHOODSCONTROLBOXCONTROLBOXGAS

Page 7

7Fan and Belts — Periodically check the condition of fanwheels and housings and belt tension. When service is neces-sary, call your dealer.Evaporator-

Page 8 - IN CASE OF TROUBLE

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Cata

Commentaires sur ces manuels